i.
Measuring cylinder
ii.
Conical flask
iii.
Beaker
iv.
Pipette
v.
Filter paper
Procedure:
According to USP
Place
the stated volume of dissolution medium at 37+0.5oC.
Place
one tablet in apparatus taking care to exclude the air bubbles from the surface
of dosage form.
Operate
the apparatus at the specific rate in individual monograph 50rpm for 15minutes.
Withdraw
the suspension from zone midway between the surface of medium and top of
rotating paddle.
Withdraw
a suspension from zone midway between the surface of dissolution medium and top
of rotating paddle from vessel walls.
Withdraw
10ml from each vessel and pour in the test tube assigned numbers.
Take
5ml from each test tube to make dilutions.
Place
them in spectrophotometer and note the absorbance of each dilution and
calculate %availability.
%
availability
Precautions:
· If
liquid aliquot is turbid, filter it otherwise make dilutions.
· Apparatus
should be calibrated with disintegration tablets (salicylic acid) and
non-disintegration tablets (prednisolone).
No comments: